HTRF 96-well low volume white plate HTRF®

All the benefits of HTRF with ELISA plate ease of use and low volume wells for low sample consumption. These 96w low volume plates can be used with all HTRF assays.

See more

All the benefits of HTRF with ELISA plate ease of use and low volume wells for low sample consumption. These 96w low volume plates can be used with all HTRF assays.

-

Overview

These plates have been specifically designed by Cisbio as an alternative to 384-well lv plate for small sample series or simply to try HTRF in a convenient environment. Cisbio’s 96-well low volume plates can be used with all HTRF assays, for example second messengers, phospho-proteins, cytokines and biomarkers. They can be used in a no-transfer protocol with suspension cells or with a transfer step for adherent cells. These plates can be read on all HTRF certified readers, thus making their implementation in your experiments really easy.

Benefits

  • SMALL SAMPLE SERIES
  • FIRST TRIALS WITH HTRF
  • COMPATIBLE WITH ALL HTRF ASSAYS

Plate characteristics

Format 96 well
Color White
Bottom Opaque
Maximum volume / well 40µl
Recommended working volume / well 20-30µl
Culture NOT culture treated
Lid Compatible
Sealer Compatible (and recommended)
Reader settings 96 half-area (except Envision)
Validation Inter-batch &intra-batch
Plate dimensions
Well dimensions

1. cAMP cell based assay in 384 well and Cisbio 96 well plates

5 µL of HEK293 cells expressing the ß2 adrenergic receptor were dispensed side-by-side in an HTRF 96-well low volume plate and in a 384-well low volume plate. Cells were stimulated for 45 min at 37°C with 5 µL of isoproterenol agonist, then 5 µL of cAMP-d2 and 5 µL of anti cAMP- cryptate from the HTRF cAMP Gs Dynamic kit were added. HTRF signal was recorded after a 1 hour incubation at RT.
384w lv plate performance
96w lv plate performance
S/B
Cells/w 1000 2000 3000; 4000
384 well lv plate 2.1 2.8 3.2 3.4
HTRF 96 well lv plate 2.1 2.5 2.9 3.4
EC50 (nM)
Cells/w 1000 2000 3000 4000
384 well lv plate 4.4 3.6 2.9 2.4
HTRF 96 well lv plate 6.7 4.8 3.3 3.0

2. ERK phosphorylation assay

Cells were grown in a T175 flask at 37°C, 5% CO2 for 48 h. They were then stimulated with 50 nM EGF for 5 min. After medium removal, the cells were lysed with 3 mL of supplemented lysis buffer #1 for 30 min at RT. Soluble fractions were collected after 10 min centrifugation. Serial dilutions of the cell lysate were performed in the supplemented lysis buffer #1. 16 µL of each dilution were dispensed for side-by-side comparison in a 384-w low-volume plate and in the HTRF 96-w low-volume. 4 µL of HTRF advanced phospho-ERK (Thr202/204) detection reagents were then dispensed and the HTRF signal was recorded after a 4 H incubation at RT.
Performance of 96w lv plate on ERK phosphorylation assay

Microplates for HTRF® Immunoassays

Designed to be used with all HTRF assays - Flyers

HTRF Product Catalog

All your HTRF assays in one document! - Catalog

A guide to Homogeneous Time Resolved Fluorescence

General principles of HTRF - Guides

HTRF 96-well low volume white plate

Characteristics of the HTRF 96-well low volume plate - Technical Notes

How HTRF compares to Western Blot and ELISA

Get the brochure about technology comparison. - Brochures